"ipAddress": "192.168.0.1",
"manualRackAndSlot": "Automatic",
"rackNumber": "0",
"slotNumber": "2"
},
"readCycleInSeconds": "1"
},
"description": "",
"dataPoints": [
{
"id": "a37d9e1fee6b4",
"name": "DatapointName",
"description": "-",
"unit": "%",
"type": "LONG",
"customData": {
"dataPointData": {
"address": "DB1.DBWORD0",
"hysteresis": "0",
"onDataChanged": false,
"acquisitionType": "WRITE"
}
}
}
]
}
Getting Configuration Details of Protocols
To get the configurations details for other protocols such as Modbus, Ethernet IP etc, the API of
AgentManagement can be used to get the configuration details. The initial configuration can be
done via UI and then using the below API config, it can be extracted and used for API calls and
later for structuring.
The json content of each protocol varies and should be extracted after an initial UI
configuration.
To get the data source configuration of AgentManagement api, refer to the endpoint "Data
Source Configuration Operations" in Agent Management Service API Specification.
Configuring data in Asset Manager
3.7 Configuring MindConnect IoT2040 using API