EasyManuals Logo

Siemens SCALANCE X308-2 User Manual

Siemens SCALANCE X308-2
322 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #198 background imageLoading...
Page #198 background image
Technical specifications
8.8 XR-300M PoE technical specifications
SCALANCE X-300
198 Operating Instructions, 05/2016, A5E01113043-20
8.8.1
Construction, installation and environmental conditions
Table 8- 100 Construction
Dimensions (W x H x D)
449 × 43.6 × 305 mm
Weight
6800 g
Degree of protection
IP20 (with closed service panel)
Table 8- 101 Installation options
Device version
(power supply)
Installation options
24 VDC
• 19" rack
• Desktop operation with adhesive feet
100 to 240 VAC 19" rack
Table 8- 102 Permitted ambient conditions
Storage/transport temperature
-40 °C to +85 ℃
Max. relative humidity in operation at 25 °C
<= 95% (no condensation)
Max. ambient temperature at operating altitude 2000 m or above:
-5 °C of the max. operating temperature
1)
3000 m or above:
-10 °C of the max. operating temperature
1)
1)
See table: "Operating temperature depending on the media modules used"
Table 8- 103 Operating temperature depending on the media modules used
Media module
1)
Installation
direction
Operating temperature
2)
Without media module
Horizontal
-40 °C to +60 ℃
Vertical
-40 °C to +50 ℃
MM992-2CUC
MM992-2CUC (C)
MM992-2CU
MM992-2M12 (C)
MM992-2VD
MM991-2
MM991-2FM
MM991-2LD
MM991-2 (SC)
MM991-2LD (SC)
MM992-2
MM992-2 (C)
MM992-2LD
Horizontal -40 °C to +60 ℃
Vertical -40 °C to +50 ℃

Table of Contents

Other manuals for Siemens SCALANCE X308-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X308-2 and is the answer not in the manual?

Siemens SCALANCE X308-2 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X308-2
CategorySwitch
LanguageEnglish

Related product manuals