Description of the device
4.3 Interfaces and signaling contact of the switches
SCALANCE X-300
Operating Instructions, 05/2016, A5E01113043-20
89
SCP
SCP992-1
850 nm
SCP992-1LD
1310 nm
STP
STP991-1
1310 nm
STP991-1LD
4.3
Interfaces and signaling contact of the switches
4.3.1
Ethernet interfaces - electrical ports
4.3.1.1
10Base-T / 100Base-TX
Transmission rate
The transmission rate of the electrical ports is 10 Mbps or as Fast Ethernet ports 100 Mbps.
Transmission mode
The transmission mode for 10Base-T / 100Base-TX is specified in the IEEE 802.3i / IEEE
802.3u standards of the Institute of Electrical and Electronic Engineers.
Autonegotiation (automatic detection of the best transmission modes) is default. The order in
which they are selected is:
100Base-TX full duplex
100Base-TX half duplex
10Base-T full duplex
10Base-T half duplex
Two communication modes are possible:
Half duplex
Two-way alternate transmission mode - it is only possible to either send or receive over
the interfaces at any one time.
Full duplex mode
Two-way simultaneous - both communication partners can send and receive at the same
time.
Connections to other switches can use half or full duplex; connections to hubs are possible
only in half duplex mode.

Table of Contents

Other manuals for Siemens SCALANCE X308-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X308-2 and is the answer not in the manual?

Siemens SCALANCE X308-2 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X308-2
CategorySwitch
LanguageEnglish

Related product manuals