Technical specifications
8.10 SFP technical specifications
SCALANCE X-300
218 Operating Instructions, 05/2016, A5E01113043-20
Table 8- 137 Electrical data: Power supply, current consumption and power loss
Device:
Transceiver
(Variant)
Effective power loss
*)
SFP991-1
(1 x 100 Mbps, LC port
optical, multimode glass, up
to max. 3 km)
0.36 W
SFP991-1LD
(1 x 100 Mbps, LC port
optical, single mode glass,
up to max. 26 km)
0.39 W
SFP991-1LH+
(1 x 100 Mbps, LC port
optical, single mode glass,
up to max. 70km)
0.47 W
SFP992-1
(1 x 1000 Mbps, LC port
optical, multimode glass, up
to max. 750m)
0.33 W
SFP992-1LD
(1 x 1000 Mbps, LC port
optical, single mode glass,
up to max. 10km)
0.41 W
SFP992-1LH
(1 x 1000 Mbps, LC port
optical, single mode glass,
up to max. 40km)
0.45 W
SFP992-LH+
(1 x 1000 Mbps, LC port
optical, single mode glass,
up to max. 70km)
0.50 W
SFP992-1ELH
(1 x 1000 Mbps, LC port
optical, single mode glass,
up to max. 120km)
0.63 W
*) Note: SFP values in 25 °C environment.
Note
Fusing of transceivers
The SFP transceivers do not have fuses. The fuse is in the modular device (M).
Note
Signaling contact and media modules
The SFP transceivers do not have a signaling contact. The signaling contact is on the
modular device (M).

Table of Contents

Other manuals for Siemens SCALANCE X308-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X308-2 and is the answer not in the manual?

Siemens SCALANCE X308-2 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X308-2
CategorySwitch
LanguageEnglish

Related product manuals