EasyManua.ls Logo

Siemens SIMATIC Field PG M6 - Page 106

Siemens SIMATIC Field PG M6
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical specifications
9.8 Active Management Technology (iAMT)
SIMATIC Field PG M6
106 Operating Instructions, 12/2018, A5E43198909-AA
4. Enter the default password "admin".
Change the password. The new password must comprise:
At least eight characters
An upper case letter
A lower case letter
A number
A special character (! @ # $ % ^ & *)
The underscore "_" and space characters are valid in the string but do not increase the
complexity of the password.
Note
If the password is no longer available, you must reset the Intel®
AMT to the default
settings.
Backup the password to protect it against loss.
5. Switch to the "Intel (R) AMT Configuration" submenu and enable "Manageability Feature
Selection".
6. Switch to the "Intel(R) ME General Settings" submenu and enable access via the network
with "Activate Network Access".
7. Confirm the dialogs that appear with "Y".
Drivers are automatically installed once with the Windows system start in the subsequent
restart.

Table of Contents

Related product manuals