EasyManua.ls Logo

Siemens SIMATIC Field PG M6 - Page 86

Siemens SIMATIC Field PG M6
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical specifications
9.4 Interface description
SIMATIC Field PG M6
86 Operating Instructions, 12/2018, A5E43198909-AA
DVI-I
Pin no.
Short designation
Meaning
Input/output
S
GND
Ground
S1
GND
Ground
C1
R
Red
Output
C2
G
Green
Output
C3
B
Blue
Output
C4
HSYNC
Horizontal synchronizing pulse
Output
C5
GND
Ground
-
CSA
GND
Ground
-
1
TX2N
TDMS data 2-
Output
2
TX2P
TDMS data 2+
Output
3
GND
Ground
4 NC Not used
5
NC
Not used
6 DDC CLK DDC clock Input/output
7
DDC CLK
DDC data
Input/output
8
VSYNC
Vertical synchronizing pulse
Output
9
TX1N
TDMS data 1-
Output
10
TX1P
TDMS data 1+
Output
11
GND
Ground
12
NC
Not used
13
NC
Not used
14
+5 V
+5 V
Output
15
GND
Ground
16
MONDET
Hotplug detect
Input
17
TX0N
TDMS data 0-
Output
18
TX0P
TDMS data 0+
Output
19
GND
Ground
20
NC
Not used
21
NC
Not used
22
GND
Ground
23
TXCP
TDMS clock +
Output
24
TXCN
TDMS clock -
Output

Table of Contents