EasyManua.ls Logo

Siemens SIMATIC FM 353 - Page 333

Siemens SIMATIC FM 353
361 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
11-31
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
Table 11-8 General data errors, machine data errors, traversing program errors, continued
Cl.
Mes-
sage/
Display
Error message,
error analysis and remedy
No.
Traversing program errors Error response: “Warning” see Table 11-2
8 (08) 25 (19) G function 2 unacceptable CBS
Cause The number programmed as G function 2 is not allowed.
or
Effect Program/block not stored
DB
Elimination Correct program, per cause
8 (08) 26 (1A) G function 3 unacceptable CBS
Cause S The number programmed as G function 3 is not allowed.
S External block change (G50) was programmed in a block
together with continuous operation for setting actual
value on the fly (G88/89).
S A tool offset (G43, G44) was called up without D number.
S In selecting a D number, the direction specification is
missing for the tool offset (G43, G44).
or
DB
Effect Program/block not stored
Elimination Correct program, per cause
8 (08) 27 (1B) M-function unacceptable CBS
Cause S The number programmed as M-function is not allowed.
S At least two of the M functions M0, M2, M18, M30, which
cancel each other out, are found in one block.
or
DB
Effect Program/block not stored
Elimination Correct program, per cause
8 (08) 28 (1C) Position/dwell time missing CBS
Cause S No dwell time specified in block with G04.
S Target position missing with external block change
(G50).
S No new actual value programmed for the function contin-
uous operation with setting actual value on the fly
(G88/89).
or
DB
Effect Program/block not stored
Elimination Correct program, per cause
8 (08) 29 (1D) Incorrect D-NO (>20) CBS
Cause The number for tool offset is greater than 20
or
Effect Program/block not stored
DB
Elimin. Correct program, per cause
Cl. = Detail event class, No. = Detail event number, CBS = checkback signals, DB = data block
Note: Value (xx) = Hexadecimal notation of the error number