EasyManua.ls Logo

Siemens SIMATIC FM 353 - Page 341

Siemens SIMATIC FM 353
361 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Data Block (AW-DB)
B-3
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
Table B-1 User data block (AWDB), continued
Adresse
absolut
CommentData typeVariable
35.5 Reserved
35.6 SSW_DIS BOOL Software limit positions disabled
35.7 Reserved
Initiation signals for single commands
36 Reserved
37.0 MD_EN BOOL Activate MD
37.1 DELDIST_EN BOOL Delete residual distance
37.2 SEARCH_F BOOL Automatic block advance
37.3 SEARCH_B BOOL Automatic block return
37.4 Reserved
37.5 RESET_AX BOOL Restart
37.6 AVALREM_EN BOOL Rescind setting of actual value
37.7 Reserved
Initiation signals for Write requests
38.0 VLEV_EN BOOL Speed levels 1, 2
38.1 CLEV_EN BOOL Frequency levels 1, 2
38.2 TRG254_EN BOOL Setpoint for incremental dimension
38.3 MDI_EN BOOL MDI block
38.4 MDIFLY_EN BOOL On-the-fly MDI block
38.5 Reserved
38.6 REFPT_EN BOOL Set reference point
38.7 AVAL_EN BOOL Set actual value
39.0 FVAL_EN BOOL On-the-fly setting of actual value
39.1 ZOFF_EN BOOL Zero offset
39.2 Reserved
39.3 PARCH_EN BOOL Modify parameters/data
39.4 DIGO_EN BOOL Digital outputs
39.5 PROGS_EN BOOL Program selection
39.6 REQAPP_EN BOOL Request application data
39.7 TEACHIN_EN BOOL Teach-in
40...41 Reserved
Initiation signals for Read requests
42.0 OPDAT_EN BOOL Basic operating data
42.1 ACT_BL_EN BOOL Active NC block
42.2 NXT_BL_EN BOOL Next NC block

Table of Contents

Related product manuals