User Data Block (AW-DB)
B-5
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
Table B-1 User data block (AW−DB), continued
Adresse
absolut
CommentData typeVariable
48.1 CLEV_D BOOL Frequency levels 1, 2
48.2 TRG254_D BOOL Setpoint for incremental dimension
48.3 MDI_D BOOL MDI block
48.4 MDIFLY_D BOOL On-the-fly MDI block
48.5 Reserved
48.6 REFPT_D BOOL Set reference point
48.7 AVAL_D BOOL Set actual value
49.0 FVAL_D BOOL On-the-fly setting of actual value
49.1 ZOFF_D BOOL Zero offset
49.2 Reserved
49.3 PARCH_D BOOL Modify parameters/data
49.4 DIGO_D BOOL Digital outputs
49.5 PROGS_D BOOL Program selection
49.6 REQAPP_D BOOL Request application data
49.7 TEACHIN_D BOOL Teach-in
50...51 Reserved
Ready signals (for Initiation signals for Read requests)
52.0 OPDAT_D BOOL Basic operating data
52.1 ACT_BL_D BOOL Active NC block
52.2 NXT_BL_D BOOL Next NC block
52.3 BLEXT_D BOOL Actual value block change
52.4 SERVDAT_D BOOL Service data
52.5 OC_ERR_D BOOL Operating error read
52.6 OT_ERR_D BOOL Operator/traversing error read
52.7 DA_ERR_D BOOL Data error read
53.0...53.2 Reserved
53.3 PARRD_D BOOL Parameter/data
53.4 DIGIO_D BOOL Dig. inputs/outputs
53.5 OPDAT1_D BOOL Additional operating data
53.6 APPDAT_D BOOL Application data
53.7 MSRRD_D BOOL Read measured values
Error signals (for Initiation signals, single settings)
54.0 SERVO_ERR BOOL Controller enable
54.1 GAUG_FLY_ERR BOOL On-the-fly measuring
54.2...54.4 Reserved