User Data Block (AW-DB)
B-6
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
Table B-1 User data block (AWDB), continued
Adresse
absolut
CommentData typeVariable
54.5 TRAV_MON_ERR BOOL Rotation monitoring
54.6 PARK_AX_ERR BOOL Parking axis
54.7 SIM_ON_ERR BOOL Simulation on
55.0...55.1 Reserved
55.2 MSR_ERR BOOL Length measurement
55.3 REF_TRIG_ERR BOOL Retrigger reference point
55.4 DI_OFF_ERR BOOL Enable input disabled
55.5 Reserved
55.6 SSW_DIS_ERR BOOL Software limit positions disabled
55.7 Reserved
Error signals (for Initiation signals, single commands)
56 Reserved
57.0 MD_ERR BOOL Activate MD
57.1 DELDIST_ERR BOOL Delete residual distance
57.2 SEARCH_F_ERR BOOL Automatic block advance
57.3 SEARCH_B_ERR BOOL Automatic block return
57.4 Reserved
57.5 RESET_AX_ERR BOOL Restart
57.6 AVALREM_ERR BOOL Rescind setting of actual value
57.7 Reserved
Error signals (for Initiation signals for Write requests)
58.0 VLEV_ERR BOOL Speed levels 1, 2
58.1 CLEV_ERR BOOL Frequency levels 1, 2
58.2 TRG254_ERR BOOL Setpoint for incremental dimension
58.3 MDI_ERR BOOL MDI block
58.4 MDIFLY_ERR BOOL On-the-fly MDI block
58.5 Reserved
58.6 REFPT_ERR BOOL Set reference point
58.7 AVAL_ERR BOOL Set actual value
59.0 FVAL_ERR BOOL On-the-fly setting of actual value
59.1 ZOFF_ERR BOOL Zero offset
59.2 Reserved
59.3 PARCH_ERR BOOL Modify parameters/data
59.4 DIGO_ERR BOOL Digital outputs
59.5 PROGS_ERR BOOL Program selection