User Data Block (AW-DB)
B-12
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
Table B-1 User data block (AWDB), continued
Adresse
absolut
CommentData typeVariable
+ 2.1 G_2_EN BOOL G function group 2
+ 2.2 G_3_EN BOOL G function group 3
+ 2.3 Reserved
+ 2.4 X_T_EN BOOL Position/dwell
+ 2.5 SR_L_EN BOOL No. of UP calls
+ 2.6 SR_N_EN BOOL UP call
+ 2.7 SKIP_EN BOOL Block skip
+ 3.0 V_EN BOOL Speed
+ 3.1 M_1_EN BOOL M function group 1
+ 3.2 M_2_EN BOOL M function group 2
+ 3.3 M_3_EN BOOL M function group 3
+ 3.4 TO_EN BOOL Tool offset
+ 3.5...+ 3.7 Reserved
+ 4 G_1_VAL BYTE G function no. of group 1
+ 5 G_2_VAL BYTE G function no. of group 2
+ 6 G_3_VAL BYTE G function no. of group 3
+ 7 Reserved
+ 8 X_T_VAL DINT Value for position/dwell
+ 12 V_VAL DINT Value for speed
+ 16 M_1_VAL BYTE M function no. of group 1
+ 17 M_2_VAL BYTE M function no. of group 2
+ 18 M_3_VAL BYTE M function no. of group 3
+ 19 TO_VAL BYTE Tool offset no.
END_STRUCT
Next NC block
362 NXT_BL STRUCT Next NC block
+ 0 PROG_NO BYTE Program number
+ 1 BLCK_NO BYTE Block number
+ 2.0 G_1_EN BOOL G function group 1
+ 2.1 G_2_EN BOOL G function group 2
+ 2.2 G_3_EN BOOL G function group 3
+ 2.3 Reserved
+ 2.4 X_T_EN BOOL Position/dwell
+ 2.5 SR_L_EN BOOL No. of UP calls
+ 2.6 SR_N_EN BOOL UP call