Technical specifications   
8.4 Technical data 
  SIMATIC IPC277G 
88  Operating Instructions, 08/2021, A5E50059956-AA 
upto 85% at 30 °C, no condensation 
Gradient ≤ 10℃/h 
upto 90% at 25/55 °C, no condensation 
Gradient ≤ 20℃/h 
Operation  1080 to 627 hPa, corresponds to an altitude of -1000 
Storage/transport  1080 to 660 hPa, corresponds to an altitude of -1000 
 
 
Multiplication factors for equipment ambient temperature of operation at altitudes up to 
3000m, tested in accordance with IEC 61131-2:2017 
Derating ratio for temperature 
1
 2 
  : Equipment ambient temperature rating at 2000 m. 
  : Atmospheric pressure and air density increases with decreasing altitude. Therefore utilization of 
the derating factor for 0 m to 2000 m for altitudes below sea level is considered conservative. 
Mechanical ambient conditions 
 
Vibration resistance, tested in accordance with IEC 60068-2-6 
•  5 to 8.4 Hz: 3.5 mm 
•  8.4 to 500 Hz: 9.8 m/s² 
•  5 to 8.4 Hz: 3.5 mm 
•  8.4 to 500 Hz: 9.8 m/s
2
 
Shock resistance, tested in accordance with IEC 60068-2-27 
•  150 m/s², 11 ms 
•  5g, 30 ms 
•  250 m/s
2
, 6 ms