EasyManua.ls Logo

Siemens SIMATIC IPC277G - Page 88

Siemens SIMATIC IPC277G
123 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical specifications
8.4 Technical data
SIMATIC IPC277G
88 Operating Instructions, 08/2021, A5E50059956-AA
Operation
upto 85% at 30 °C, no condensation
Gradient 10/h
Storage/transport
upto 90% at 25/55 °C, no condensation
Gradient 20/h
Atmospheric pressure
Operation 1080 to 627 hPa, corresponds to an altitude of -1000
to 3000 m
Storage/transport 1080 to 660 hPa, corresponds to an altitude of -1000
to 3500 m
Multiplication factors for equipment ambient temperature of operation at altitudes up to
3000m, tested in accordance with IEC 61131-2:2017
Altitude
Derating ratio for temperature
1
0 to 2000
2
m
1.0
3000 m
0.9
1
: Equipment ambient temperature rating at 2000 m.
2
: Atmospheric pressure and air density increases with decreasing altitude. Therefore utilization of
the derating factor for 0 m to 2000 m for altitudes below sea level is considered conservative.
Mechanical ambient conditions
Vibration resistance, tested in accordance with IEC 60068-2-6
Operation
Except DIN-Rail:
5 to 8.4 Hz: 3.5 mm
8.4 to 500 Hz: 9.8 m/s²
Storage/transport
5 to 8.4 Hz: 3.5 mm
8.4 to 500 Hz: 9.8 m/s
2
Shock resistance, tested in accordance with IEC 60068-2-27
Operation
150 m/s², 11 ms
5g, 30 ms
Storage/transport
250 m/s
2
, 6 ms

Table of Contents

Related product manuals