Technical specifications
8.4 Technical data
SIMATIC IPC277G
88 Operating Instructions, 08/2021, A5E50059956-AA
Operation
upto 85% at 30 °C, no condensation
Gradient 10/h
Storage/transport
upto 90% at 25/55 °C, no condensation
Gradient 20/h
Atmospheric pressure
Operation 1080 to 627 hPa, corresponds to an altitude of -1000
to 3000 m
Storage/transport 1080 to 660 hPa, corresponds to an altitude of -1000
to 3500 m
Multiplication factors for equipment ambient temperature of operation at altitudes up to
3000m, tested in accordance with IEC 61131-2:2017
Altitude
Derating ratio for temperature
1
0 to 2000
2
m
1.0
3000 m
0.9
1
: Equipment ambient temperature rating at 2000 m.
2
: Atmospheric pressure and air density increases with decreasing altitude. Therefore utilization of
the derating factor for 0 m to 2000 m for altitudes below sea level is considered conservative.
Mechanical ambient conditions
Vibration resistance, tested in accordance with IEC 60068-2-6
Operation
Except DIN-Rail:
5 to 8.4 Hz: 3.5 mm
8.4 to 500 Hz: 9.8 m/s²
Storage/transport
5 to 8.4 Hz: 3.5 mm
8.4 to 500 Hz: 9.8 m/s
2
Shock resistance, tested in accordance with IEC 60068-2-27
Operation
150 m/s², 11 ms
5g, 30 ms
Storage/transport
250 m/s
2
, 6 ms

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC IPC277G and is the answer not in the manual?

Siemens SIMATIC IPC277G Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC IPC277G
CategoryIndustrial PC
LanguageEnglish

Related product manuals