Technical specifications
8.4 Technical data
SIMATIC IPC277G
Operating Instructions, 08/2021, A5E50059956-AA
87
USB
On the interface panel:
4 × USB 3.1 (900mA)
On the motherboard:
2 × USB 2.0 vertical (500 mA)
You can find additional information in the section "Power demand of the
components (Page 89)".
DP
Connection of a DP monitor
Keyboard, mouse
Connection via USB port
1
In BIOS Setup, you can configure support for RS232/RS422/RS485 for COM1 and COM2 ports.
8.4.2 Ambient conditions
Climatic ambient conditions
For permitted mounting positions, see section Preparing for installation (Page 19).
Temperature, tested in accordance with IEC 60068-2-1, IEC 60068-2-2 and IEC 60068-2-14
7“, 10 At an ambient temperature > 40 °C, the device must be operated in an operating area in accordance
with RAL.
When installed vertically in horizontal format
without M.2 Module: 0 °C to +50 °C
with M.2 Module load max. 5W: 0 °C to +45 °C
When installed inclined in horizontal format,
Vertical inclination maximum ±45 °
without M.2 Module: 0 °C to +50 °C
with M.2 Module load max. 5W: 0 °C to +45 °C
When installed upright in vertical format,
(Power supply is located at the top)
without M.2 Module: 0 °C to +50 °C
with M.2 Module load max. 5W: 0 °C to +45 °C
12, 15
At an ambient temperature > 40 °C, the device must be operated in an operating area in accordance
with RAL.
When installed vertically in horizontal format
0 °C to +50 °C
When installed inclined in horizontal format,
Vertical inclination maximum ±45 °
0 °C to +45 °C
When installed upright in vertical format,
(Power supply is located at the top)
0 °C to +45 °C
19, 22, 24
At an ambient temperature > 40 °C, the device must be operated in an operating area in accordance
with RAL.
When installed vertically in horizontal format
0 °C to +45 °C
When installed inclined in horizontal format,
Vertical inclination maximum ±45 °
0 °C to +40 °C
When installed upright in vertical format,
(Power supply is located at the top)
0 °C to +40 °C
Temperature during storage/transport
-20 °C to +60 °C
Gradient
Operation: Max. 10 °C/h
Storage: 20 °C/h, no condensation
Relative humidity, tested in accordance with IEC 60068-2-78, IEC 60068-2-30