Configuring with Web Based Management
5.6 "Interfaces" menu
SCALANCE W760/W720 to IEEE 802.11n Web Based Management
182 Configuration Manual, 11/2014, C79000-G8976-C350-03
Alternative DFS Channel
If you have enabled the "DFS" function, on the "Basic" page, specify the alternative
channel here. If you want the access point to search for a free channel itself, use "Auto".
If a primary user was detected both on the main and alternative channel, the access point
automatically searches for a free channel.
If you want to use a fixed channel, select the required channel from the drop-down list.
HT Channel Width [MHz]
You can specify the channel bandwidth only with the IEEE 802.11n transmission
standard.
The following settings are possible.
20
Channel bandwidth 20 MHz
40 up
Channel bandwidth 40 MHz. The configured channel and the neighboring channel
above it are used.
40 down
Channel bandwidth 40 MHz. The configured channel and the neighboring channel
below it are used.
Note
Channel bandwidth 40 MHz and frequency band 2.4 GHz
If the access point detects another access point on the configured channel or on
neighboring channels, the access point changes the channel bandwidth from 40 MHz
to 20 MHz. If you set a "free" channel on the access point, the ac
cess point uses the
channel bandwidth 40 MHz.
Table 2 has the following columns:
Radio
Shows the available WLAN interfaces in this column.
Available Channels
This box displays the permitted channels. The display depends on the wireless approvals
of the currently selected country and the settings for "Allowed Channels".
Table 3 has the following columns:
Radio
Shows the WLAN interface.
Port
Shows the VAP interface.
Enabled
To use the required VAP interface, select this check box.
SSID
Enter the SSID of the WLAN. The length of the character string for SSID it is 1 to 32
characters.
The ASCII code 0x20 to 0x7e is used for the SSID.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W722-1 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W722-1 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W722-1
CategoryControl Unit
LanguageEnglish

Related product manuals