Configuring with Web Based Management
5.6 "Interfaces" menu
SCALANCE W760/W720 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C350-03
183
Broadcast SSID
disabled
The SSID is no longer sent in the beacon frame of the access point. This means that
the SSID is not visible for other devices. Only clients that know the SSID of the access
point and that are configured with it can connect to the access point. The "Any SSID"
option must be disabled on these clients.
enabled
The SSID is sent in the Beacon frame of the access point and is visible for other
devices. This means that clients on which the "Any SSID" option is enabled can also
connect to the access point.
Note
Since no encryption is used for the SSID transfer, this function can only provide basic
protection agai
nst unauthorized access. The use of an authentication method (for
example WPA2 (RADIUS) or WPA2
-PSK if this is not possible) provides higher security.
You must also expect that end devices may have problems with access to a hidden
SSID.
WDS only
If you enable this option, the access point only supports communication via WDS. In
WDS mode, all access points must use the same channel.
WDS ID
Enter the WDS ID. The WDS ID can be a maximum of 32 characters long.
To establish a WDS connection, enter this WDS ID on the WDS Partner.
ASCII code 0x20 to 0x7e is used for the WDS ID.
Procedure
1. Select the required channel from the "Channel" drop-down list.
2. Enter network name in the "SSID" input box for the corresponding WLAN interface and
port.
3. Select the "Enabled" check box for the relevant WLAN interface and the port.
4. Click the "Set Values" button.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W722-1 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W722-1 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W722-1
CategoryControl Unit
LanguageEnglish

Related product manuals