EasyManua.ls Logo

Siemens SIMATIC PC 670 - Problems Using External Modules; Fault Screen

Siemens SIMATIC PC 670
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault Diagnosis
Release 04/02
6-2
Panel PC 670 Computing Unit, Equipment Manual
6.1 Problems Using External Modules
Fault screen
Computing unit crashes during boot routine.
Cause
The following causes are possible:
Double assignment of input/output addresses,
Double assignment of hardware interrupts and/or DMA channels,
Signal frequencies or signal levels are not maintained,
Deviating assignment of the connector
Remedy
Checking the computer configuration:
S If the computer configuration corresponds to state on delivery, please contact
your technical service department.
S If the computer configuration has been modified, restore the state on delivery;
to do this, remove the external modules and restart the computer:
If the computing unit crashes again, contact the technical service
department.
If the fault no longer occurs, the external module used was the cause of the
fault. Replace the module with a Siemens module or get advice from the
supplier of the external module.