EasyManuals Logo

Siemens Simatic S7-300 CPU 31xC Series User Manual

Siemens Simatic S7-300 CPU 31xC Series
272 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
Table of contents
S7-300, CPU 31xC and CPU 31x: Installation
viii Operating Instructions, Edition 08/2004, A5E00105492-05
4.11.3.6 Connectors and other components for Ethernet...................................................................... 4-56
4.11.3.7 Example of a PROFINET Subnet ............................................................................................ 4-57
4.11.3.8 Example of a PROFINET IO system........................................................................................ 4-59
4.11.4 Routed network transitions....................................................................................................... 4-60
4.11.5 Point-to-point (PtP)................................................................................................................... 4-62
4.11.6 Actuator/sensor interface (ASI) ................................................................................................ 4-63
5 Installing ................................................................................................................................................. 5-1
5.1 Installing an S7-300 ................................................................................................................... 5-1
5.2 Installing the mounting rail ......................................................................................................... 5-3
5.3 Mounting modules onto the rail.................................................................................................. 5-7
5.4 Labeling the modules................................................................................................................. 5-9
6 Wiring ..................................................................................................................................................... 6-1
6.1 Requirements for wiring the S7-300 ..........................................................................................6-1
6.2 Bonding the Protective Conductor to the Mounting Rail ............................................................ 6-3
6.3 Adjusting the Power Supply Module to local Mains Voltage...................................................... 6-4
6.4 Wiring the Power Supply Module and the CPU ......................................................................... 6-5
6.5 Wiring Front Connectors ............................................................................................................ 6-7
6.6 Plugging the front connectors into modules............................................................................. 6-10
6.7 Labeling the module I/O ........................................................................................................... 6-11
6.8 Connecting shielded cables to the shielding contact element ................................................. 6-12
6.9 Wiring the MPI / PROFIBUS DP bus connectors..................................................................... 6-15
6.9.1 Wiring the bus connector ......................................................................................................... 6-15
6.9.2 Setting the terminating resistor on the bus connector ............................................................. 6-16
6.10 RJ45 Ethernet connector ......................................................................................................... 6-17
7 Addressing.............................................................................................................................................. 7-1
7.1 Slot-specific addressing of modules .......................................................................................... 7-1
7.2 User-specific addressing of modules .........................................................................................7-3
7.2.1 User-specific addressing of modules ......................................................................................... 7-3
7.2.2 Addressing digital modules ........................................................................................................ 7-3
7.2.3 Addressing analog modules....................................................................................................... 7-5
7.2.4 Addressing the integrated I/Os of CPU 31xC ............................................................................ 7-6
7.3 Consistent data .......................................................................................................................... 7-8
8 Commissioning ....................................................................................................................................... 8-1
8.1 Overview .................................................................................................................................... 8-1
8.2 Commissioning procedure ......................................................................................................... 8-1
8.2.1 Procedure: Commissioning the hardware.................................................................................. 8-1
8.2.2 Procedure: Software commissioning .........................................................................................8-3
8.3 Commissioning check list........................................................................................................... 8-5
8.4 Commissioning the Modules...................................................................................................... 8-7
8.4.1 Inserting/Replacing a Micro Memory Card (MMC)..................................................................... 8-7
8.4.2 Initial power on ........................................................................................................................... 8-9
8.4.3 CPU memory reset by means of mode selector switch ............................................................. 8-9
8.4.4 Formatting the Micro Memory Card (MMC) ............................................................................. 8-12
8.4.5 Connecting the programming device (PG)............................................................................... 8-13

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Simatic S7-300 CPU 31xC Series and is the answer not in the manual?

Siemens Simatic S7-300 CPU 31xC Series Specifications

General IconGeneral
SeriesS7-300 CPU 31xC
Power Supply24 V DC
Communication InterfacesMPI, PROFIBUS DP
Programming LanguagesLAD, STL, FBD, SCL
Operating Temperature0°C to +60°C
Memory48 KB - 512 KB
Dimensions40 x 125 x 130 mm (varies by model)

Related product manuals