Saving and Compiling
S7-GRAPH for S7 300/400 Programming Sequential Control Systems
8-4 C79000-G7076-C526-01
On Saving
Include instance DB:
If you select this option, whenever a function block is compiled or downloaded,
S7-Graph checks whether the instance DB requires updating and if necessary
updates it automatically.
If you do not select this option, you must create or update the instance DB
manually with the menu command File > Generate Instance DB.
Caution:
If you have set the option "Message with ALARM_SQ/ALARM_S
(SFC17/SFC18)" in the "Messages" tab page (Options > Application Settings
menu command) the instance DB is automatically included. If the instance DB is
deleted, make sure you only recreate it with S7-Graph, otherwise messages are
lost.
Generate Reference Data:
If you select this option, the reference data are created automatically when you
save the block.
If you do not select the option, you can nevertheless create or update the
reference data manually with the menu command Options > Reference Data.
Generate PDIAG Data:
If you select this option, S7-Graph generates diagnostic data that can be
displayed on an operator interface system.
Addresses in Source Files
The addresses can be saved in source files either in absolute or symbolic format.
Absolute
Select this option to access the addresses in absolute format.
Symbolic
Select this option to access the addresses in symbolic format. The symbols
used must be defined in the symbol table.
Automatically create a new window when a step is opened
If you select this option, when you double-click a step it is displayed at the
single-step level in a separate window.
Save window arrangement on closing
If you select this option, the settings are saved when you exit the editor and will
be displayed again next time you start an editor session. The option applies to
the settings for the application and for the active block. If no block is open, the
block-specific settings remain unchanged.
Use only one status job for monitoring
If you select this option, only one status job is used for monitoring.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-GRAPH and is the answer not in the manual?

Siemens SIMATIC S7-GRAPH Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC S7-GRAPH
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals