Notes on Configuration
S7-GRAPH for S7-300/400 Programming Sequential Control Systems
C79000-G7076-C526-01
14-11
SW_MAN
SW_AUTO
SW_TAP
Autom.
Inch
Man
&
&
&
FB sequencer
AUTO_ON
TAP_ON
MAN_ON
With this logic, the sequencer returns to the state set by the signals
automatic/inching/manual after one cycle.