Installation
4.9 Installing and removing the shaft-mounted gearbox
BA 2030 (2KJ4)
46 Operating Instructions, 07/2020, A5E50009094A/RS-AL
The torque arm can be fitted in various positions, depending on the hole circle pitch.
Figure 4-12 Toggle lever design
For a toggle lever design, derive the force in the range of 90° ± 20°.
Procedure
1. Clean the contact surfaces between the housing and the torque arm.
2. Tighten the bolts to the specified torque.
You have now mounted the torque arm.
Table 4- 10 Tightening torque for screws of strength class 8.8
Thread size
M8
M10
M12
M16
M20
M24
M36
Tightening torque [Nm]
25
50
90
210
450
750
2600