BA 2030 (2KJ4)
Operating Instructions, 07/2020, A5E50009094A/RS-AL
59
8.1 General notes about maintenance work
Unintentional starting of the drive component
Secure the drive component to prevent it from being started up unintentionally.
Attach a warning notice to the start switch.
Improper maintenance
Only authorized qualified personnel may perform the maintenance and servicing. Only
original parts supplied by Siemens AG may be installed.
Only qualified personnel may perform the inspection, maintenance and servicing work.
Please observe the General information and safety notes (Page 7).
Table 8- 1 Maintenance measures
Monitor and check the geared
motor for unusual noise, vibra-
Daily; if possible, more frequent-
ly during operation.
Check the housing temperature.
After 3 hours, on the first day,
thereafter monthly.
After the first day, and then
every 3000 operating hours, or
at the latest after 6 months.
Checking and changing lubri-
cants (Page 60)
Check the oil level sensor
Regularly and after oil changes.
Checking the oil level sensor
(optional) (Page 76)
Checking the oil quality
(Page 63)
First oil change after commis-
sioning.
10000 operating hours or at the
Checking and changing lubri-
cants (Page 60)
Every 2 years or
10000 operating hours
1)
Visual inspection of the gear-
box and shaft sealing ring for
After the first day, thereafter
monthly.
Checking the gearbox for leaks
(Page 75)
When required, replace the
breather valve.
Replacing the vent valve
(Page 75)
Depending on degree of soiling,
at least every 6 months.
Cleaning the gearbox (Page 76)