EasyManua.ls Logo

Siemens SIMOGEAR BA 2030 - VLplus Bearing System Options

Siemens SIMOGEAR BA 2030
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BA 2030 (2KJ4)
Operating Instructions, 07/2020, A5E50009094A/RS-AL
59
Service and maintenance
8
8.1 General notes about maintenance work
WARNING
Unintentional starting of the drive component
Secure the drive component to prevent it from being started up unintentionally.
Attach a warning notice to the start switch.
NOTICE
Improper maintenance
Only authorized qualified personnel may perform the maintenance and servicing. Only
original parts supplied by Siemens AG may be installed.
Only qualified personnel may perform the inspection, maintenance and servicing work.
Please observe the General information and safety notes (Page 7).
Table 8- 1 Maintenance measures
Remedy
Interval
Description of work
Monitor and check the geared
motor for unusual noise, vibra-
tions, and changes.
Daily; if possible, more frequent-
ly during operation.
Operation (Page 55)
Check the housing temperature.
After 3 hours, on the first day,
thereafter monthly.
Check the oil level.
After the first day, and then
every 3000 operating hours, or
at the latest after 6 months.
Checking and changing lubri-
cants (Page 60)
Check the oil level sensor
Regularly and after oil changes.
Checking the oil level sensor
(optional) (Page 76)
Check the oil quality.
Every 6 months.
Checking the oil quality
(Page 63)
First oil change after commis-
sioning.
After approximately
10000 operating hours or at the
latest after 2 years.
Checking and changing lubri-
cants (Page 60)
Subsequent oil changes.
Every 2 years or
10000 operating hours
1)
.
Visual inspection of the gear-
box and shaft sealing ring for
leaks.
After the first day, thereafter
monthly.
Checking the gearbox for leaks
(Page 75)
When required, replace the
breather valve.
Once a year.
Replacing the vent valve
(Page 75)
Clean the gearbox.
Depending on degree of soiling,
at least every 6 months.
Cleaning the gearbox (Page 76)

Table of Contents