Commissioning
5.4 Installing the oil temperature monitoring device
BA 2030 (2KJ4)
Operating Instructions, 07/2020, A5E50009094A/RS-AL
51
Mounting the sensor for oil temperature monitoring
1475 Resistance thermometer comprising
â‘£ Compression nut
Figure 5-4 Mounting the sensor for oil temperature monitoring
Procedure
1. Remove the sealing cap 1477 from the sensor pocket 1476.
2. Unscrew the cable gland ②, ③, ④ on the sensor cable ⑤.
3. Carefully insert the sensor â‘ into the sensor pocket 1476 until to the base of the drill hole.
4. Screw the intermediate unit â‘¡ into the drill hole of the sensor pocket 1476 using SW11 and
4 Nm of tightening torque.
5. Insert the sealing element â‘¢ into the intermediate unit â‘¡.
6. Tighten the compression nut â‘£ using SW11 and 4 Nm of tightening torque.
You have mounted the sensor for oil temperature monitoring.