5 Commissioning the Router Kit WLAN / LTE
5.1 Preparing the hardware
Application example for SIMOTICS CONNECT 400 - Router KitInbetriebnahme- und Montagehandbuch 43
5 Commissioning the Router Kit WLAN / LTE
5.1 Preparing the hardware
Requirements
All components are installed as described under "Installing the Router Kit WLAN / LTE in the
installation enclosure (page 11)".
Procedure
34. Insert the SIM card into the LTE module (SCALANCE M876-4).
35. Attach the LAN cable between the LTE module and a PC with adapter.
36. Supply the Router Kit with a voltage of 230 V AC (SITOP PSU100C).
5.2 Setting up interfaces
Download of PST (Primary Setup Tool)
You can find the download on the Internet
(https://support.industry.siemens.com/cs/ww/en/view/19440762).
Requirements
The IP addresses to be assigned must be in the same address range as the IP address
of the LTE module (default IP of the LTE module is 192.168.1.1).
You require administrator rights to download the PST.
You need a ready-for-use LAN adapter to set the IP address.

Table of Contents

Other manuals for Siemens SIMOTICS CONNECT 400

Related product manuals