5 Commissioning the Router Kit WLAN / LTE
5.4 Configuring SCALANCE M876-4
Application example for SIMOTICS CONNECT 400 - Router KitInbetriebnahme- und Montagehandbuch 60
71. Confirm your entries by clicking on "Set Values".
72. The changes are saved automatically after 60 s. To save the changes immediately, click
on the link that appears "Changes will be saved automatically in 60 seconds. Press "Write
Startup Config" to save immediately" and then on "Write Startup Config".
5.4.5 Updating the DHCP server
Procedure
73. Switch to the menu "System > DHCP".