7 Commissioning the Router Kit LAN / LTE
7.3 Configuring SCALANCE M876-4
Application example for SIMOTICS CONNECT 400 - Router KitInbetriebnahme- und Montagehandbuch 89
8. Set the following properties in the "Internet Protocol Version 4 (TCP/IPv4) Properties"
dialog:
Set the check mark for "Use the following IP address".
IP address: 192.168.1.10
(Fixed IP address of the adapter. You can also select any other IP address that is in
the address range of the LTE module.)
Default gateway: 192.168.1.1
(In general: The IP address of the LTE module is entered as default gateway)
Set the check mark for "Use the following DNS server addresses".
Preferred DNS server: 192.168.1.1
(In general: The IP address of the LTE module is entered as preferred DNS server)
Figure 7-4 Entering Internet protocol properties
7.3 Configuring SCALANCE M876-4
7.3.1 Logging in to the Web-based Management Tool
Procedure
9. Commission the device.
10. To log in to the Web-based Management Tool, enter the IP address of the LTE module
(192.168.1.1) in the browser.

Table of Contents

Other manuals for Siemens SIMOTICS CONNECT 400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS CONNECT 400 and is the answer not in the manual?

Siemens SIMOTICS CONNECT 400 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS CONNECT 400
CategoryControl Unit
LanguageEnglish

Related product manuals