7 Commissioning the Router Kit LAN / LTE
7.3 Configuring SCALANCE M876-4
Application example for SIMOTICS CONNECT 400 - Router KitInbetriebnahme- und Montagehandbuch 99
33. In the "DHCP Server" tab, set the check marks for "DHCP Server" and "Enable". You can
set the range via the Lower and Upper Address. Make sure to stay in the same subnet
(192.168.1.x).
Figure 7-16 Setting the DHCP server
34. In the "DHCP Options" tab, make the settings as shown in the figure.
Figure 7-17 Setting the DHCP options