EasyManua.ls Logo

Siemens SIMOTICS DC 1GG6 - Page 140

Siemens SIMOTICS DC 1GG6
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Applications
The above-mentioned tightening torques apply for the following applications:
Case A
Applies to electrical connections in which the permissible torque is normally limited by the
bolt materials and/or the current carrying capacity of the insulators, with the exception of
the busbar connections in case B.
Case B
Applies to bolts screwed into components made from materials with lower property class
(e. g. aluminum) and to bolts with property class 8.8 according to ISO 898-1.
Case C
Applies to bolts with property class 8.8 or A4-70 according to ISO 898-1, however only to
bolts screwed into components made from materials with higher property class, e.g. cast
iron, steel or cast steel.
Note
Non-standard tightening torques
Different tightening torques for electrical connections and bolted connections for parts with
flat seals or insulating parts are specified in the relevant sections and drawings.
Technical data and drawings
B.1 Tightening torques for screw and bolt connections
SIMOTICS DC 1GG6
140 Operating Instructions 02/2016