01.04 Function descriptions
SIEMENS AG 6SG7000-0BA76 9-3
SIMOTRAS HD Operating Instructions
P046 (0)
B
B
B
B
.01
.02
.03
.04
Selection of binectors ("indexed" parameter with 4 indices)
Parameter number = P046, factory setting = 0 (i. e. fixed value 0, this
factory setting applies to all the indices of P046)
U181 (0)
KK
Selection of a double-word connector (SW 1.9 and later)
Parameter number = U181, factory setting = 0 (i.e. fixed value 0%)
The selected setting can be entered in the empty field (fields). The value in brackets next to the
parameter number is the factory setting of the selection parameter.
The following rules apply to the selection of double-word connectors (SW 1.9 and later):
U181 (0)
KK
KK9498
9498
Double-word connector to double-word connector selection:
The double word for subsequent processing comprises:
LOW word = LOW word of double-word connector (KK9498)
HIGH word = HIGH word of double-word connector (KK9498)
U181
KK
K0401
401
Connector to double-word connector selection:
The double word for subsequent processing comprises:
LOW word = 0
HIGH word = selected connector (K0401)
P044
K
KK9498
9498
Double-word connector to connector selection:
HIGH word of the double-word connector (KK9498) is connected to another
block,
the LOW word of the double-word connector (KK9498) is not used
.01
.02
U751 (0)
9498
9498
KK9498
KK9498
L
H
K
K
There are exceptions in the selection of transmission data for the serial
interfaces and in the transmission of optional expansion modules
(technology and communications modules, SIMOLINK module):
If the same double-word connector is entered in two contiguous indices of
the selection parameter, the entire value (the LOW and HIGH word) will be
used.
.01
.02
U751 (0)
KK9498
KK9499
H
H
9498
9499
K
K
If different double-word connectors are entered in two contiguous indices of
the selection parameter, in both cases only the HIGH word of the two
double-word connectors will be used.