01.04 Connections
SIEMENS AG 6SG7000-0BA76 6-17
SIMOTRAS HD Operating Instructions
6.2.2.4 List of recommended RI suppression filters
Rated current
RI suppression
filter (A)
RI suppression filter
Order number
Terminal
cross-
section
(mm²)
Ground
(kg)
Dimensions
HxWxD
(mm)
36
6SE7023-4ES87-0FB0 25 3,7 245x101x86
80 6SE7027-2ES87-0FB0 50 9,5 308x141x141
120 6SE7031-0ES87-0FA0 50 10 348x171x141
180 6SE7031-8ES87-0FA0 95 13 404x171x141
500 6SE7033-7ES87-0FA0 Connecting
lug
49 590x305x154
1000 6SE7041-0ES87-0FA0 Connecting
lug
90 840x465x204
Important technical data of RI suppression filters:
Rated supply voltage 3AC 380-460 V (± 15%)
Rated frequency 50/60 Hz (± 6%)
Operating temperature
0° C to +40° C
Degree of protection IP20 (EN60529)
IP00 with 500 A and above
For further technical data about filters, please refer to the Operating Instructions:
SIMOVERT Master Drives RI Suppression Filters EMC Filters, Order number: 6SE7087-6CX87-
0FB0
.