EasyManua.ls Logo

Siemens SIMOTRAS 6SG7050 - 18 Appendix Compatibility with SIMOTRAS HE (6 GA4625 Series)

Siemens SIMOTRAS 6SG7050
604 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
01.04 Appendix
SIEMENS AG 6SG7000-0BA76 18-1
SIMOTRAS HD Operating Instructions
18 Appendix
18.1 Compatibility with SIMOTRAS HE (6GA4625 series)
It is desirable to make the inputs and outputs of the SIMOTRAS HD (6SG70 series) as compatible
as possible with its predecessor (the SIMOTRAS HE, 6GA4625 series). The following parameters
therefore need to be changed from the factory settings:
Caution:
With these parameter settings, the drive-specific (crane) control according to Section 6.4
is not active.
Terminal on SIMOTRAS HE (6GA4625
series)
Settings or measures necessary on SIMOTRAS HD
(6SG70 series) to implement the functions of the
terminal in the left hand column
Term. 72 (FS ... enable setpoint) P662.001 = 500 [G180.3]
P662.002 = 500 [G180.3]
Term. 73 (FR ... enable controller) P654.001 = 502 [G130.1]
P654.002 = 502 [G130.1]
P661.001 = 502 [G180.1]
P661.002 = 502 [G180.1]
U617 = 0 .. Term. 37 inactive [G130.1]
U618 = 0 .. Term. 38 inactive [G180.1]
Term. 74 (FZ ... enable additional setpoint) U249 = 504 [K13.4]
P401.001 .. 4 = 60% .. 100% [K12.5]
U628 = 95% [G160.6]
Term. 75 (VE .. pre-limit switch) U607.001 = 506 [G135.5]
U607.002 = 506 [G135.5]
U608.001 .. 4 = setpoint reduction factor [G135.5]
Term. 76 (TL .. inch anticlockwise) *) P430.001 = 508 [G127.2]
P431.001 = 402 [G127.2]
P402 = inch anticlockwise setpoint [G120.1]
Term. 77 (TR .. inch clockwise) *) P430.002 = 510 [G127.2]
P431.002 = 403 [G127.2]
P403 = inch clockwise setpoint [G120.1]
Term. 76 + Term. 77 (reduced start pulse)
(i.e. same control as terminals
76 and 77)
U347.001 = 508 [B205.7]
U347.002 = 510 [B205.7]
U347.003 = 1 [B205.7]
U657.001 = 9377 [G150.5]
U657.002 = 9377 [G150.5]
U652.001 .. 4 = start pulse reduction factor [G150.4]
If this function is used, P402 must be = P403
Term. 78 (RS .. reset fault memory) P665.001 = 512 [G180.1]
P665.002 = 512 [G180.1]
*) The “inch” function on SIMOTRAS HE corresponds to the “fixed setpoint“ on SIMOTRAS HD

Table of Contents