01.04 Parameter list
SIEMENS AG 6SG7000-0BA76 11-61
SIMOTRAS HD Operating Instructions
PNU Description Value range
[Unit]
No. indices See
Change
11.37 Binary outputs
(see also Section 8, Sheet G112)
P770
*
(G112)
Control word for binary selectable outputs
i001: 0 Binary selectable output at terminal 46 is not inverted
1 Binary selectable output at terminal 46 is inverted
i002: 0 Binary selectable output at terminal 48 is not inverted
1 Binary selectable output at terminal 48 is inverted
i003: 0 Binary selectable output at terminal 50 is not inverted
1 Binary selectable output at terminal 50 is inverted
i004: 0 Binary selectable output at terminal 52 is not inverted
1 Binary selectable output at terminal 52 is inverted
0 to 1
1
Ind: 4
FS=0
Type: O2
P052 = 3
P051 = 40
Online
P771
*
(G112)
Source for output value at binary output terminal 46
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: None
FS=252
Type: L2
P052 = 3
P051 = 40
Online
P772
*
Source for output value at binary output terminal 48
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Online
P773
*
(G112)
Source for output value at binary output terminal 50
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Online
P774
*
(G112)
Source for output value at binary output terminal 52
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Online
P775
(G112)
Delay for output value at binary output 1
The logic level at the binary selectable output changes only if the internal
signal level remains constant for the set delay period (internal signal level
changes which do not last as long as this delay period are not switched
through to the output)
0 to 10000
[ms]
1ms
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Online
P776
(G112)
Delay for output value at binary output 2
The logic level at the binary selectable output changes only if the internal
signal level remains constant for the set delay period (internal signal level
changes which do not last as long as this delay period are not switched
through to the output)
0 to 10000
[ms]
1ms
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Online
P777
(G112)
Delay for output value at binary output 3
The logic level at the binary selectable output changes only if the internal
signal level remains constant for the set delay period (internal signal level
changes which do not last as long as this delay period are not switched
through to the output)
0 to 10000
[ms]
1ms
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Online
P778
(G112)
Delay for output value at binary output 4
The logic level at the binary selectable output changes only if the internal
signal level remains constant for the set delay period (internal signal level
changes which do not last as long as this delay period are not switched
through to the output)
0 to 10000
[ms]
1ms
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Online
11.38 Configuration of serial interfaces on basic converter
G-SST 1 (RS485 / RS232 on X300) (see also Section 8, Sheet G170 and Section 9)
P780
*
(G170)
Selection of protocol for G-SST1 basic converter interface
0 Setting has no function
2 USS protocol
8 for factory purposes
9 For internal factory test purposes
0, 2, 8, 9
1
Ind: None
FS=2
Type: O2
P052 = 3
P051 = 40
Offline