Installation 01.04
5-12 SIEMENS AG 6SG7000-0BA76
SIMOTRAS HD Operating Instructions
Recommended way of fitting the pulse encoder
Do not use force!
ca. 52
13
12
+0/-0,1
Fan housing motor
Motor shaft
NDE
Pulse encoder
Tighten
pointed screw
after installation
Do not insert
any fixing screws in this hole!
Do not insert
any fixing screws in this hole!!
Provide
adequate spacing!
Connecting pin
(fits into hollow
shaft of encoder)
Three connecting pins with
different thread sizes
(M5, M6, M8) are provided
Allow encoder connecting cable
to hang freely!
Select a clamp that is large
enough to permit the
connecting cable to move
freely!