01.04 Connections
SIEMENS AG 6SG7000-0BA76 6-3
SIMOTRAS HD Operating Instructions
n>
Centrifugal switch
MCB
Centrifugal brake operator
Fuse monitoring
circuit on
SIMOTRAS
power section
Acknowledge signal
"Ready"
signal
83
84
81
82
K01
k01
Enable
P24_S
SIMOTRAS HD
Brake
control
85
86
230V
~
87564321
38
34
Q73
L1
L2 L3
4U1
4V1
4W1
q73
q47
Power section Converter fan
3AC 50-60Hz
110 - 500V
3AC 50-60Hz
400V
Electronics
I> I> I>
Q2
Q1
135 1321
2
46
14 22
13
14
U1 V1 W1
5U1
5W1
5N1
NC
I> I> I>
13 21
14 22
135
246
13
14
Q47
k7
M
3~
UV W
PE
Centrifugal
brake operator
1AC 50-60Hz
230V
Electronics
5U1
5W1
5N1
<1> <2>
<1> Electronics power supply 230 V
~
<2> Electronics power supply 400 V
~oder
46 47
Q
Crane switch
k01
K71
k71
K7
230V
~

Table of Contents