Maintenance 01.04
13-4 SIEMENS AG 6SG7000-0BA76
SIMOTRAS HD Operating Instructions
Replacement of fan on D400 / 225 – 525 Mre converters
4U1
4V1
4W1
PE
1
2
The fan is mounted on the underside of the converter.
Remove connector
a.
Use a T20 screwdriver to undo the two Torx screws
s.
Lift the fan using the fixing straps and pull out downwards.
Installation:
Push fan box up along the rear panel right up over the fixing clips.
Tighten the two Torx screws
s with 2.5 Nm.
Insert connector
a.