EasyManua.ls Logo

Siemens Sinamics G120 CU240S DP - Page 182

Siemens Sinamics G120 CU240S DP
238 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Functions
5.11 Operation in fieldbus systems
Frequency inverter
182 Operating Instructions, 08.10. 2008, t.b.d.
Rules for the parameter range
The bit for selecting the parameter page functions as follows:
When it is set to 1, an offset of 2000 is applied in the converter to the parameter number
(PNU) transferred in the parameter channel request before the data is transferred.
,1'

DGFEI H
Figure 5-33 IND page index (acyclic)
,1'

DGFEI H
Figure 5-34 IND page index (cyclic)
Table 5- 63 Regulations for setting the PNU
Page index Bit Parameter range
a d c b f e 9 8
Hex value + PNU
0000 … 1999 0 0 0 0 0 0 0 0 0x00 0 – 7CF
2000 … 3999 1 0 0 0 0 0 0 0 0x80 0 – 7CF
4000 … 5999 0 0 0 1 0 0 0 0 0x10 0 – 7CF
6000 … 7999 1 0 0 1 0 0 0 0 0x90 0 – 7CF
8000 … 9999 0 0 1 0 0 0 0 0 0x20 0 – 7CF
32.000 … 33.999 0 0 0 0 0 1 0 0 0x04 0 – 7CF
64.000 … 65.999 0 0 0 0 1 0 0 0 0x08 0 – 7CF
Table 5- 64 Sample coding of a parameter number in PKE and IND for P8820, index 16
PKE IND
decimal xx 820 32 16
hex xx 334 20 10

Table of Contents

Related product manuals