Fieldbuses
Function Manual, 04/2018, FW V4.7 SP10, A5E34229197B AE
9
Fundamental safety instructions
1
1.1
General safety instructions
WARNING
Danger to life if the safety instructions and residual risks are not observed
If the safety instructions and residual risks in the associated hardware documentation are
not observed, accidents involving severe injuries or death can occur.
Observe the safety instructions given in the hardware documentation.
Consider the residual risks for the risk evaluation.
WARNING
Malfunctions of the machine as a result of incorrect or changed parameter settings
As a result of incorrect or changed parameterization, machines can malfunction, which in
turn can lead to injuries or death.
Protect the parameterization (parameter assignments) against unauthorized access.
Handle possible malfunctions by taking suitable measures, e.g. emergency stop or
emergency off.
1.2
Warranty and liability for application examples
Application examples are not binding and do not claim to be complete regarding
configuration, equipment or any eventuality which may arise. Application examples do not
represent specific customer solutions, but are only intended to provide support for typical
tasks.
As the user you yourself are responsible for ensuring that the products described are
operated correctly. Application examples do not relieve you of your responsibility for safe
handling when using, installing, operating and maintaining the equipment.

Table of Contents

Other manuals for Siemens SINAMICS G120P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120P and is the answer not in the manual?

Siemens SINAMICS G120P Specifications

General IconGeneral
Frequency Range0 Hz to 550 Hz
Ambient Temperature-10°C to +50°C
Storage Temperature-40°C to +70°C
Relative Humidity5% to 95% (non-condensing)
Voltage Range200 V to 240 V, 380 V to 480 V, 500 V to 690 V
Output Voltage0V to input voltage
Control TypeVector control, V/f control
Protection ClassIP20, IP55
Communication InterfacesPROFIBUS, PROFINET, Modbus RTU
Cooling MethodAir cooling
AltitudeUp to 2000 m without derating
Power Range0.37 to 630 kW