Communication via EtherNet/IP
4.5 Supported objects
Fieldbuses
Function Manual, 04/2018, FW V4.7 SP10, A5E34229197B AE
95
Ethernet/IP motor data object
0
1
2
3
4
5
6
7
19
20
U/f with linear characteristics
U/f with linear characteristics and FCC
U/f with parabolic characteristics
U/f with parameterizable characteristics
U/f with linear characteristics and ECO
U/f for precise frequency drive (textile sector)
U/f for precise frequency drive and FCC
U/f for parabolic characteristics and ECO
U/f with independent voltage setpoint
Closed-loop speed control (without encoder)
Closed-torque control (without encoder)
1
0
0
0
0
0
0
0
0
2
Open loop speed (Frequency)
Vendor specific mode
Vendor specific mode
Vendor specific mode
Vendor specific mode
Vendor specific mode
Vendor specific mode
Vendor specific mode
Vendor specific mode
Closed loop speed control
Siemens Drive Object, Instance Number: 32C hex
Get Attribute single
Get Attribute single
Set Attribute single
Table 4- 16 Class Attribute
1 get UINT16 Revision
3 get UINT16 Num of Instances
Table 4- 17 Instance Attribute
p0010 commissioning parameter filter
3 … 18 get STW1 STW1 bit-by-bit access:
Attr.3 = STW1.0
20 … 35 get ZSW1 ZSW1 bit-by-bit access:
Attr.20 = ZSW1.0
Main actual value (actual frequency)
37 get, set Ramp Up Time p1120[0] ramp-function generator
38 get, set Ramp Down Time p1121[0] ramp-function generator
42 get, set OFF3 Ramp Down
Time
p1135[0] OFF3 ramp-down time
p2200[0] technology controller enable