1: Only those elements of an array that have changed are output
Bit3 R variables (only for INI files)
0: All R variables are output
1: Only R variables not equal to '0' are output
Bit4 Frames (only for INI files)
0: All frames are output
1: Only those frames that are not zero frames are output.
Bit5 Tool data (cutting edge parameters) (only for INI files)
0: All tool data are output
1: Only those tool data not equal to '0' are output.
Bit6 Buffered system variables ($AC_MARKER[], $AC_PARAM[] only for INI files)
0: All system variables are output
1: Only those system variables not equal to '0' are output
Bit7 Synchronized actions GUD (for INI files only)
0: All Syna GUD are output
1: Only those Syna GUD not equal to '0' are output
Active: The change in the data becomes active on the start of the upload for the next
range.
The settings are only active, if MD11212 $MN_UPLOAD_CHANGES_ONLY=FALSE.
11212 UPLOAD_CHANGES_ONLY N01, N05 -
- Data backup type for an active file system. BOOLEAN Immediately
-
- - TRUE - - 2/2 M
Description: Only values of the selected file of the active file system
that deviate from the default setting are backed up.
TRUE = only the values of the selected file of the active file system that deviate
from the standard setting are backed up (a differential data backup)
The value of MD11210 $MN_UPLOAD_MD_CHANGES_ONLY than has no effect.
FALSE = all values of the selected file of the active file system are backed up.
Same significance as MD11210 $MN_UPLOAD_MD_CHANGES_ONLY=0.
However, if MD11210 $MN_UPLOAD_MD_CHANGES_ONLY is not equal to 0, then this
setting is active.
11240 PROFIBUS_SDB_NUMBER N01, N05 K4, FBU
- SDB number DWORD PowerOn
-
808d-me42 4 -1, -1, -1, -1 -1, -1, -1, -1 7, 7, 7, 7 2/2 M
808d-me62 4 0, -1, -1, -1 -1, -1, -1, -1 7, 7, 7, 7 2/2 M
808d-te42 4 -1, -1, -1, -1 -1, -1, -1, -1 7, 7, 7, 7 2/2 M
808d-te62 4 0, -1, -1, -1 -1, -1, -1, -1 7, 7, 7, 7 2/2 M
808d-mte40 4 -1, -1, -1, -1 -1, -1, -1, -1 7, 7, 7, 7 2/2 M
808d-mte60 4 0, -1, -1, -1 -1, -1, -1, -1 7, 7, 7, 7 2/2 M
Description: Number of the system data block (SDB) used for configuring the I/Os.
The following assignments of MD11240[0,1,2,3] are prmitted:
[0, -1, 0, 0] telegram 136 and axis extension NX10.3
[1, -1, 1, 1] telegram 136 and axis extension NX15.3 (= default)
[2, -1, 2, 2] telegram 136 and axis extension NX15.3, 1x CU320-2 PN (only PPU 26x.3/28x.