Value: Meaning:
0 Routine _N_ASUP_SPF is not activated for either RET or REPOS.
Bit0 = 1 User-specific routine _N_ASUP_SPF is executed for RET, the routine supplied
by the system is executed for REPOS.
Bit1 = 1 User-specific routine _N_ASUP_SPF is executed for REPOS, the routine
supplied by the system is executed for RET
Bit0= + bit1 = 3 User-specific routine _N_ASUP_SPF is executed for both RET and REPOS
Bit2 = 1 User ASUB _N_ASUP_SPF is searched for first in _N_CMA_DIR
Related to:
MD11612 $MN_ASUP_EDIT_PROTECTION_LEVEL
11612 ASUP_EDIT_PROTECTION_LEVEL N01 K1
- Protection level of the user-specific ASUB program DWORD PowerOn
-
- - 2 0 7 2/2 M
Description: Protection level of the user-specific ASUB program for RET and/or REPOS
The data is active only if MD11610 $MN_ASUP_EDITABLE is set to a value other than 0.
This machine data defines the protection level of the program _N_ASU_CUS.
MD irrelevant for:
MD11610 $MN_ASUP_EDITABLE set to 0
Related to:
MD11610 $MN_ASUP_EDITABLE
11622 PROG_EVENT_PATH N01 -
- Call path for PROG_EVENT BYTE PowerOn
-
808d-me42 - 2 0 3 0/0 S
808d-me62 - 2 0 3 0/0 S
808d-te42 - 2 0 3 0/0 S
808d-te62 - 2 0 3 0/0 S
808d-mte40 - 3 0 3 7/2 M
808d-mte60 - 3 0 3 7/2 M
Description: Path on which the user program set with MD11620 $MN_PROG_EVENT_NAME is called in
response to an event-driven program call configured with MD20108 $MC_PROG_EVENT_MASK:
0: /_N_CMA_DIR
1: /_N_CUS_DIR
2: /_N_CST_DIR
3: Search path in the sequence /_N_CUS_DIR, /_N_CMA_DIR, and /_N_CST_DIR
11717 D_NO_FCT_CYCLE_NAME EXP, N12, N07 K1
- Subroutine name for D function replacement STRING PowerOn
-
- - - - - 2/2 M
Description: Cycle name for replacement routine of the D function.
If a D function is programmed in a part program block, then, depending on machine data
MD10717 $MN_T_NO_FCT_CYCLE_NAME, MD10719 $MN_T_NO_FCT_CYCLE_MODE and MD10718
$MN_M_NO_FCT_CYCLE_PAR, the MD subprogram defined in MD11717 $MN_D_NO_FCT_CYCLE_NAME
is called.
The programmed D number can be polled in the cycle via system variable $C_D /
$C_D_PROG.
Machine data
3.2 General machine data
Parameter Manual
76 List Manual, 01/2017