MD10715 $MN_M_NO_FCT_CYCLE,
MD20094 $MC_SPIND_RIGID_TAPPING_M_NR,
MD22254 $MC_AUXFU_ASSOC_M0_VALUE
MD10814 $MN_EXTERN_M_NO_MAC_CYCLE,
MD20095 $MC_EXTERN_RIGID_TAPPING_M_NR
10815 EXTERN_M_NO_MAC_CYCLE_NAME EXP, N12 H2
- Name of subroutine for M function macro call STRING PowerOn
-
- 30 - - - 2/2 M
Description: Name of the subprogram started by a call via the M function defined by MD10814
$MN_EXTERN_M_NO_MAC_CYCLE[n].
10816 EXTERN_G_NO_MAC_CYCLE EXP, N12 FBFA
- Macro call via G function DOUBLE PowerOn
-
- 50 -1., -1., -1., -1., -1., -1.,
-1., -1....
- - 2/2 M
Description: G number for calling a macro.
The name of the subprogram is stated in MD10817 $MN_EXTERN_G_NO_MAC_CYCLE_NAME[n].
If the G function specified with MD10816 $MN_EXTERN_G_NO_MAC_CYCLE[n] is programmed in
a part program block, the subprogram defined in MD10817
$MN_EXTERN_M_NO_MAC_CYCLE_NAME[n] is started. All addresses programmed in the block
are written in the corresponding $C_xx variables.
No subprogram call is executed if a subprogram call is already active via an M/G macro
or
an M
replacement. If a standard G function is programmed in this case, this code is
executed. Otherwise, alarm 12470 is issued.
MD10816 $MN_EXTERN_G_NO_MAC_CYCLE[n] is only active in the external language mode G291.
Only a single subprogram call may be included in any one block. This means that only
a single M/G function replacement may be programmed in a block, and no additional
subprogram (M98) or cycle call may be included in the block.
Furthermore, a subprogram return and a part program end are not permitted in the same
block.
Alarm 14016 is issued in case of a conflict.
10817 EXTERN_G_NO_MAC_CYCLE_NAME EXP, N12 FBFA
- Name of subroutine for G function macro call STRING PowerOn
-
- 50 - - - 2/2 M
Description: Name of the subprogram started by call via the G function defined by MD10816
$MN_EXTERN_G_NO_MAC_CYCLE[n].
10818 EXTERN_INTERRUPT_NUM_ASUP EXP, N12 FBFA
- Interrupt number for ASUB start (M96) BYTE PowerOn
-
- - 1 1 8 1/1 M
Description: Number of the interrupt input starting an asynchronous subprogram activated in ISO
mode. (M96 <program number>)
Machine data
3.2 General machine data
Parameter Manual