Appendix
A.9 Information List
SIPROTEC, 7SJ62/64, Manual
C53000-G1140-C207-2, Release date 01.2008
665
284 Set Point 37-1 Undercurrent
alarm (SP. 37-1 alarm)
Set Points(MV) OUT On
Off
* * LED BO 135 244 1 Yes
285 Set Point 55 Power factor alarm
(SP. PF(55)alarm)
Set Points(MV) OUT On
Off
* * LED BO 135 245 1 Yes
301 Power System fault
(Pow.Sys.Flt.)
Device, General OUT On
Off
On
Off
135 231 2 Yes
302 Fault Event (Fault Event) Device, General OUT * on 135 232 2 Yes
303 sensitive Ground fault (sens Gnd
flt)
Device, General OUT On
Off
* ON 135 233 1 Yes
320 Warn: Limit of Memory Data ex-
ceeded (Warn Mem. Data)
Device, General OUT On
Off
**LEDBO
321 Warn: Limit of Memory Parame-
ter exceeded (Warn Mem. Para.)
Device, General OUT On
Off
**LEDBO
322 Warn: Limit of Memory Operation
exceeded (Warn Mem. Oper.)
Device, General OUT On
Off
**LEDBO
323 Warn: Limit of Memory New ex-
ceeded (Warn Mem. New)
Device, General OUT On
Off
**LEDBO
356 >Manual close signal (>Manual
Close)
P.System Data 2 SP * * * LED BI BO 150 6 1 Yes
395 >I MIN/MAX Buffer Reset (>I
MinMax Reset)
Min/Max meter SP on * * LED BI BO
396 >I1 MIN/MAX Buffer Reset (>I1
MiMaReset)
Min/Max meter SP on * * LED BI BO
397 >V MIN/MAX Buffer Reset (>V
MiMaReset)
Min/Max meter SP on * * LED BI BO
398 >Vphph MIN/MAX Buffer Reset
(>VphphMiMaRes)
Min/Max meter SP on * * LED BI BO
399 >V1 MIN/MAX Buffer Reset (>V1
MiMa Reset)
Min/Max meter SP on * * LED BI BO
400 >P MIN/MAX Buffer Reset (>P
MiMa Reset)
Min/Max meter SP on * * LED BI BO
401 >S MIN/MAX Buffer Reset (>S
MiMa Reset)
Min/Max meter SP on * * LED BI BO
402 >Q MIN/MAX Buffer Reset (>Q
MiMa Reset)
Min/Max meter SP on * * LED BI BO
403 >Idmd MIN/MAX Buffer Reset
(>Idmd MiMaReset)
Min/Max meter SP on * * LED BI BO
404 >Pdmd MIN/MAX Buffer Reset
(>Pdmd MiMaReset)
Min/Max meter SP on * * LED BI BO
405 >Qdmd MIN/MAX Buffer Reset
(>Qdmd MiMaReset)
Min/Max meter SP on * * LED BI BO
406 >Sdmd MIN/MAX Buffer Reset
(>Sdmd MiMaReset)
Min/Max meter SP on * * LED BI BO
407 >Frq. MIN/MAX Buffer Reset
(>Frq MiMa Reset)
Min/Max meter SP on * * LED BI BO
408 >Power Factor MIN/MAX Buffer
Reset (>PF MiMaReset)
Min/Max meter SP on * * LED BI BO
409 >BLOCK Op Counter (>BLOCK
Op Count)
Statistics SP On
Off
* LED BI BO
412 >Theta MIN/MAX Buffer Reset (>
Θ MiMa Reset)
Min/Max meter SP on * * LED BI BO
501 Relay PICKUP (Relay PICKUP) P.System Data 2 OUT ON m LED BO 150 151 2 Yes
502 Relay Drop Out (Relay Drop Out) Device, General SP * *
510 General CLOSE of relay (Relay
CLOSE)
Device, General SP * *
No. Description Function Type
of
In-
for-
matio
n
Log Buffers Configurable in Matrix IEC 60870-5-103
Event Log ON/OFF
Trip (Fault) Log ON/OFF
Ground Fault Log ON/OFF
Marked in Oscill. Record
LED
Binary Input
Function Key
Relay
Chatter Suppression
Type
Information Number
Data Unit
General Interrogation