Appendix
A.7 Assembly Object
SIRIUS 3RW5 EtherNet/IP communication module
Manual, 05/2019, A5E45131885002A/RS-AA/001
79
Instance 100 (0x64): Process image output (PIQ)
Read access (get, r) and write access (set, w) to the process image output (PIQ) are
possible.
Byte
Bit
Data format
Process image
3RW
52
1)
55
2)
0
0
BOOL
Motor CW
r/w
r/w
1
BOOL
Motor CCW
-
r/w
3 BOOL Reset r/w r/w
4
BOOL
Emergency start
-
r/w
3)
5
BOOL
Self-test (user-test)
r/w
r/w
6
BOOL
Creep speed
-
r/w
1
0
BOOL
Output 1
4)
-
r/w
1
BOOL
Output 2
4)
-
r/w
2
BOOL
Parameter set bit 0
5)
-
r/w
3
BOOL
Parameter set bit 1
5)
-
r/w
7
BOOL
Disable quick-stop
-
r/w
2
0
BOOL
Output 3
4)
-
r/w
3
BOOL
Pump cleaning
-
r/w
3
0
BOOL
Manual operation local - input controlled
r/w
r/w
1
BOOL
Use alternative stopping mode
-
r/w
2
BOOL
Motor standstill
-
r/w
1)
Supported by SIRIUS 3RW52 soft starter
2)
Supported by SIRIUS 3RW55 soft starter
3)
Control data is relevant for EX applications
4)
You can assign the control data "Output 1", "Output 2" and "Output 3" to the digital outputs 1, 2 and 4 of the
3RW55 soft starter in any order via the digital output actions. You will find more information in the Equipment Manual of
the 3RW5 soft starter.
5)
Explanation in the following table
More information
The following table describes the assignment of the process images "Parameter set bit 0"
and "Parameter set bit 1":
Parameter set
Parameter set bit 0
Parameter set bit 1
Process image error
1
1
Parameter set 1 (PS1)
0
0
Parameter set 2 (PS2)
1
0
Parameter set 3 (PS3)
0
1