Compact transmitter version:
Ex d e [ia] ia IIC T3-T6 Gb
Ex tD A21 IP67 T** °C (** pipe temperature +13K, but not less than T85 °C
(MAG 3100 / MAG 3100 P)
Ex d e [ia] ia IIB T3-T6 Gb
Ex tD A21 IP67 T** °C (** pipe temperature +18K, but not less than T85 °C
(MAG 1100 / MAG 1100 F)
*YHUBQQ
For sensors:
Refer to sensor certificates:
MAG 3100 / MAG 3100 P: Sira 07ATEX1182X (DN 15-DN300); Sira 03ATEX3339X (DN350-
DN2000)
MAG 1100 / MAG 1100 F: Sira 07ATEX3181X
Safety parameters associated with the remote transmitter version
Table 2-1
Intrinsically safe data
Sensor electrode input (Terminals 0, 81, 82, 83, 84 - "ia circuits")
IIB IIC
U
O
30 V DC 30 V DC
I
O
6.1 mA 6.1 mA
C
O
560 nF 66 nF
L
O
1 H 0.96 H
P
O
45.5 mW 45.5 mW
Safety notes