Scale parameters and functions
8.6 DR 5 Tare / zero memory
SIWAREX WP251
Manual, 12/2015, A5E37203357A
81
Version identi-
Current data record
USHORT
2
r
1
1
65635
1217
Effective tare
weight - from
specification 1,
2 or 3
Current tare weight
(tare setting)
FLOAT 4 rwP 0 0 Depends
on speci-
fication in
DR 3
1218
Effective tare
weight (semi-
automatic)
Current tare weight
(semi-automatic)
FLOAT 4 rwP 0 0 Depends
on speci-
fication in
1220
Zero by power-
on (value when
switching on)
Current zeroing
weight (affected by
switch-on)
FLOAT 4 rwP 0 Depends
on speci-
fication in
Depends
on speci-
fication in
1222
Zero weight
(semi-
automatic)
Current zero setting
weight (semi-
automatic)
FLOAT 4 rwP 0 Depends
on speci-
fication in
Depends
on speci-
fication in
1224
Current zero
tracking weight
(Page 82)
Current zero setting
weight
(zero tracking)
FLOAT 4 rwP 0
Depends
on speci-
fication in
Depends
on speci-
fication in
1226
Dead load
(Page 82)
Dead load calculat-
ed during automatic
calibration
FLOAT 4 r 0
Depends
on speci-
fication in
Depends
on speci-
fication in
1228
Effective tare weight - from specification 1, 2 or 3
A preset tare weight can be specified in data record DR 15. It is activated with command
(1013). The "Delete Tare" command deactivates the preset tare weight. This does not delete
the specification in data record DR 15.
Effective tare weight (semi-automatic)
The corresponding command (see command 1011) applies the current gross weight as the
active tare weight. From this point on, the activated tare weight is factored into the weight
calculations. The "Delete tare" command deactivates the active tare weight.