Errors and messages
9.6 Operating errors
SIWAREX WP251
Manual, 12/2015, A5E37203357A
167
2114 Maximum corrective action
exceeded
2114
The corrective active of the controller was greater than
the maximum corrective action configured in DR 24.
2115 Log error 2115 Error while reading a log in DR 46.
2116 Set point too large 2116 The set point specified in DR 20 is greater than the
residual quantity on the scale (removal mode). Weigh-
ing can still be carried out using the "Continue weigh-
ing" and subsequent "Rest emptying" commands!
A recovery point was successfully set
2097 Restore point loaded
A recovery point was successfully loaded
2098 Standard parameters
2098 The standard parameters were successfully loaded
2099 Factory settings loaded
The factory settings were successfully loaded
Table 9- 2 Data and command errors
Group error, at least one data/operating error present
Issued command code is unknown. Check the command code.
6051 Command not possi-
ble now
6051 - The desired command could not be executed because, for exam-
ple, another process is already active at this time. Additional
information contains details.
4500 , because a fault is present
, because no standstill occurred
, because module is already waiting for standstill
, because CPU is missing or not ready
, because emptying active
, because SecureDisplay is missing or not visible
4681 , because display command does not match the current display
6052 Service command
6052 Commands from the Service commands group could not be exe-
cuted. Additional information contains details.
, because service mode is not active
, because write protection active