Scale parameters and functions
8.3 DR 3 Calibration parameters
SIWAREX WP251
66 Manual, 12/2015, A5E37203357A
SecureDisplay version
SecureDisplay version UBYTE 12 "V3.0
- - - 1069
Smallest zoom factor of
SecureDisplay (Page 75)
Minimum zoom factor
of SecureDisplay (%)
USHORT 2 0 - - - 1075
Grid frequency (Page 75) Switchover of line
frequency 50/60 Hz
0: 50 Hz
USHORT 2 0 0 1 - 1085
You can select any name, but it may not exceed 12 characters. You can enter any
designation.
Note
The scale name cannot be changed after officia
l verification.
The following weight units are available for selection: milligram, gram, kilogram, metric ton,
ounce, pound, short ton, and long ton The weight unit selection has no effect on the internal
weight calculation. It involves only ASCII characters. Thus, all parameters with weight must
be specified with appropriate conversion when there is a change of weight unit.
The gross identifier specifies the letter, B (for brutto) or G (for gross) to be used in the
display for a gross weight value.