The UTMC OTU licence controls whether or not connection to Stratos is supported
see section 7.4.4.
Ethernet Configuration
Ethernet can be fully configured manually if required but configuration can be
minimised by using DHCP.
To connect the equipment to Stratos perform the following:
1. Set the date and time (System - Settings - System Date & Time - Set System
Date & Time web page).
2. On the System - Settings - Comms Stratos web page:
Set the Tenant Pass Phrase.
Set the Site Location.
Set the Site Name.
3. Set the profile to Stratos (System Settings web page).
4. Check that Ethernet is suitably configured (System - Settings - Comms -
DSL/Fibre web page). Using the Stratos profile sets this to DHCP. If this not
suitable then configure as required.
5. Connect the Ethernet port to a network which has connectivity to the services
described above.
Setting the Site Name, Site Location & Tenant Pass Phrase
These items are set on the System Settings Comms Stratos configuration web
page.
Specifying a Tenant Pass Phrase prior to initial connection allows the equipment to
be automatically allocated to the specified tenant on initial connection to Stratos. If
the Tenant Pass Phrase is not specified at the time of initial connection then the
equipment will be allocated to the Siemens Support team who can then make the
allocation when required based on the outstation name, unique site id and
destination tenant. This item has no effect after initial connection to Stratos.