Loading...
Mobility, Intelligent Traffic Systems
Sopers Lane, Poole, Dorset, BH17 7ER
Security classification
Unrestricted
Page
138 of 154
Version
7
Status
Issued
Last Editor
manpreet.jeerh
Date
January 2020
Document Name
ST950 ICM Handbook
Document No.
667/HE/45950/000
Peripherals
Identify all connected GSPI peripherals
and reports card types, firmware &
versions.
This example shows two cards
connected:
1 - 24/16 I/O Card
2 - Intelligent Detector Backplane
Checks communications with each
peripheral
If cards do not have inventory
information programmed some fields
are omitted or identified as ‘unknown’
GSPI Inventory
GSPI:1 HW:
Prt:667/1/32990/951
Iss:02
Serial:xxxxxxxx
GSPI:1 FW:
Prt: 32998
Iss:0.1.3.4
GSPI:1 HWID: 193
24in 16out
link ok
GSPI:2 HW:
Prt:
667/1/46090/000
Iss:01
Serial:xxxxxxxx
Intelligent Det
Backplane
GSPI:2 FW:
Prt: 32998
Iss:0.1.3.4
GSPI:1 HWID: 194
16in
link ok
Test Status
Pass: GSPI
Test ID
Ethernet
Test: Ethernet Ping
Ethernet
Ping test over Ethernet interface.The IP
address used is gateway address For
use in manufacturing the controller uses
an IP address stored in an XML file on a
USB memory stick that is plugged into
the controller.
Ping:
i/f OK
xxx.xxx.xxx.xxx OK
Test Status
Pass: Ethernet Ping
Test ID
USB Device
Test: PcPing
USB Device
Ping test over USB device interface. IP
address is hardwired to 172.29.100.10
which is the address adopted by the
connected PC.
USB PC:
172.29.100.10 OK
Test Status
Pass: PcPing