Tests the RS232 modem connection
using a loopback connector.
Where no loopback is detected ‘not
conn’ is displayed for each failed
connection:
TXD-RXD
DTR-CTS
DTR-RI
RTS-DSR
Tests the Auxiliary RS232 connection
using a loopback connector.
Where no loopback is detected ‘not
conn’ is displayed for each failed
connection:
TXD-RXD
DTR-CTS
RTS-DSR
EFC passes control of self test back to
Primary CPU – EFC Inventory tests
complete
Primary control
of self test
Primary Driver tests begin; checks that
the Phase Bus system can be started
but does not yet switch on the lamp
supply
Waits for ZXO
synchronization
and checks the
mains
frequency
Source of ZXO detected and reported.
If the Processor cannot synchronize to
the mains zero cross-over signal, then
Self-Test waits indefinitely at this point
with the red system error LED
illuminated. Check/replace the
connection between LSLS#1 and the
CPU Card. Then try replacing LSLS#1
or the CPU Card
Mains frequency measured and
reported