Detector +ve Supply Solar Signal Solar +ve Supply
Detector -ve Supply Solar -ve Supply
Figure 14 – SK2 Detector Supply and Solar Cell connections
See section 4.17 and Figure 39 for details of the cable connections to the Solar
Cell.
The following table details the connections on the HPU.
-48V DC Connection for 8 off Reg. Signs
Reg Sign Return (+)
Reg-Sign Supply (-)
-24V DC supply for powering Loop Detector Cards and
above ground detectors. Connects to a 12-way terminal
block on the side panel of the cabinet. Det Com (+) and
Det Sup (-)
Connection for 24V DC Solar Cell
Connect Solar cell supply leads to Solar + and Solar -,
observing correct polarity. Connect Solar Cell signal to
Sol Sig.
Connection to CPU Card and LPU for relay control.
PL1 and PL2 are identical. PL2 connects to Main CPU
Card. PL1 connects to PL2 of second HPU unit, if fitted.
Reg. Sign current monitor output to LSLS card.